Pro Star Mechanical

Serving Vancouver Island & the Gulf Islands

Pro Star Mechanical Technologies Ltd.

Heating | Plumbing | Radiant Floor Heating | Air Conditioning | Heat Pumps | Geothermal Heat Pumps | HVAC | Boilers

Victoria, BC: 250-383-4558 | Courtenay, BC: 250-331-0888

 

UniChiller RC™ - The Reverse Cycle Cooling and Heating System

Reverse Cycle Chiller

Provides both hot and cold water for total indoor comfort

Using the efficiency of water, the the UniChiller RC provides chilled water for cooling and also reverse cycles to provide hot water for heating, giving the end-use the very best in indoor comfort.

The UniChiller is a self-contained and pre-charged air-to-water heat pump.

The UniChiller has an operational sound level of only 66 dB(A)

Unico's UniChiller RC - front view

Benefits of The UniChiller RC™

  • Ideal for zoning as there are no freeze-up problems caused by partial load conditions. The UniChiller compressor operates only on water temperature either sensed by the temperature controller inside the unit or by a separate external temperature controller.
  • Piping as simple or complex as required.
  • Quiet operation, less than 66 dB(A).
  • It can be placed at a remote location with properly sized piping and pump (up to 300 ft).
  • Available with or without a high head pump.
  • Available only with R-407C (ozone friendly) refrigerant.
  • Multiple UniChillers may be banked together to increase capacity and provide redundancy for increased reliability.

Quiet Operation - the UniChiller RC includes fans with a swept-wing configuration - which ensures quiet operation. The UniChiller RC is much quieter than conventional condensing units and chillers, as it had a side fan discharge rather than a top fan discharge.

Save Space - zoning of multiple conditioned areas allows for multiple air handling units to be run in conjunction with one outdoor unit. However, for larger residential and/or commercial projects, The UniChiller RC can be banked with multiple chiller units to provide the cooling and heating loads necessary for larger spaces.

Remote Location - valuable space near the home is not lost to the UniChiller because the unit uses water as the cooling/heating medium. And since all the refrigerant used in the unit is completely sealed and not circulated to the conditioned space, there is no danger of refrigerant escaping and the system never needs to be recharged.

Sealed System & Factory Charged - the UniChiller RC can be installed quickly and easily in the field and never requires further field charging. And it's been specifically designed to make maintenance and repair simple, with a stainless steel pump for longevity and error-free operation.


Unico's UniChiller RC - inside view
Features of The UniChiller RC™
  • Reverse Cycle Operation
  • Swept-wing Fan Construction
  • Side Fan Discharge
  • Sealed Refrigerant System
  • Stainless Steel Pump
  • Low Maintenance
  • Minimal Footprint
  • Long-lasting Protective Finish

Click here for a .pdf brochure of the UniChiller.


UniChiller RC Specifications

Model #
Nominal Capacity, Btu/hr (kW)
Sound level*, dB
Electrical Data
Refrigerant
Shipping Weight, lbs (kg)
Price, CDN funds
Min. Circuit Ampacity
Max Fuse/Circuit Breaker
Voltage
Hz
Amps @ 230V
Type
Charge, lbs (kg)
UCHR-036
36,000 (10.8)
68
29.1
45
208/230
60
19
R-407C
5.1 (2.3)
310 (141)
$8.304.00
UCHR-060
60,000 (17.6)
41.7
60
25.5
7.9 (3.6)
340 (154)
$9,977.00

*Sound measurement taken at 3 feet from the front of the unit.

Model #
Pump Data
Other Date
Min Flow, GPM
Max Flow, GPM
Head Pressure at Min Flow Rate*, psi
Pump Size, HP (W)
Pump Speed, RPM
Supply Water Temp °F (°C)
Min. System Volume, Gal. (L)
Approx. chiller volume, Gal. (L)
Min. Expansion Tank Size**, Gal. (L)
UCHR-036
7.2
14
21.7
- (560)
3450
44 (6.7)
25 (95)
1.0 (3.8)
1.0 (3.8)
UCHR-060
12
19.5
1-1/3 (1007)

* Evaporator pressure drop is included.
** Not included, field installed.

UniChiller RC Cooling Performance*

Model
UCHR-036
UCHR-060
Outside Temperature
Capacity
Power Input
W
Efficiency
Capacity
Power Input
W
Efficiency
°F
°C
Btu/hr
kW
EER
COP
Btu/hr
kW
EER
COP
82
27.8
36,200
10.6
3300
11.0
3.2
56,700
16.6
4790
11.8
3.5
95
35.0
33,900
9.9
3820
8.9
2.6
52,600
15.4
5460
9.6
2.8
100
37.8
33,000
9.7
4040
8.2
2.4
50,800
14.9
5750
8.8
2.6
105
40.6
32,100
9.4
4270
7.5
2.2
48,900
14.3
6060
8.1
2.4
110
43.3
31,100
9.1
4520
6.9
2.0
46,800
13.7
6380
7.3
2.1

* Based on compressor data. At 44°F leaving water temp. and min. required flow rate.

UniChiller RC Heating Performance*

Model
UCHR-036
UCHR-060
Outside Temperature
Capacity
Power
Input (W)
Efficiency
Capacity
Power
Input (W)
Efficiency
°F
°C
Btu/hr
kW
EER
COP
Btu/hr
kW
EER
COP
10
-12.2
25,800
7.6
3310
7.8
2.3
36,100
10.6
4630
7.7
2.3
17
-8.3
27,100
7.9
3320
8.2
2.4
38,100
11.2
4660
8.2
2.4
33
0.6
30,900
9.1
3330
9.3
2.7
43,900
12.9
4750
9.2
2.7
47
8.3
35,300
10.
3340
10.6
3.1
50,900
14.9
4830
10.5
3.1
55
12.8
38,600
11.3
11.6
3.4
56,000
16.4
4880
11.5
3.4
65
18.3
43,800
12.8
13.1
3.8
63,700
18.7
4940
12.9
3.8

*Based on compressor data. At 120°F leaving water temperature and minimum required flow rate.

Back To Top
E-mail Pro Star


Pro Star Victoria Head Office
524 William Street
Victoria, BC V9A 3Y9
Phone: 250-383-4558
Fax: 250-383-6990

Vancouver Island BBB
Pro Star Courtenay Branch
Unit 212 - 2459 Cousins Avenue
Courtenay, BC V9N 3N6
Phone: 250-331-0888
Fax: 250-331-0889

E-mail: info@prostar-mechanical.com

All prices are in Canadian dollars and are subject to change without notice. Prices may be applicable to state/provincial taxes. Shipping/freight charges may apply.


Copyright © 2010 Pro Star Mechanical Technologies Ltd